Item/Parameter
C3
Unit
Rated load (Emax)
25,40,60,100,200,350
Kg
Maximum numbers of load cell verification Intervals
3000
d
Minimum numbers of load cell verification Intervals
0.01
% of rated load
Rated output
2.0±0.1%
mV/V
Combined error
0.015
±% of rated output
Temperature effect on sensitivity
0.0012
±% of rated output/°C
Temperature effect on zero balance
0.0008
Zero balance
1.0
±% of rated output/
Input resistance
405±10
Ω (Ohms)
Output resistance
350±3
Insulation resistance
≥5000
MΩ(Mega-Ohms)
Safe overload
150
% of rated capability
Ultimate overload
300
Operating temperature range
-20~+70 / -20~+160
C/F
Recommend excitation
8~12
V(DC or AC)
Maximum excitation
18
Material of elastomer
Aluminum alloy
Protection class
IP67/IP68
LAB-130
LAE-D
LAD-A
Contact: Terence
Phone: 0086-18969804310
Tel: 0086-574-86141701
Email: sales@yahengchina.com